The Office Sterilization Solution - 100% Ethylene Oxide Sterilization
When cost or space is limited, and load volumes do not necessitate a large sterilizer, Anprolene® gently sterilizes a wide variety of delicate items that heat and moisture can damage. A combination of ventilation and purge systems ensure that Ethylene Oxide (EtO) exposure levels are below OSHA prescribed limits. Easy installation requires only 110V AC outlet and a dedicated exhaust line to the outside.
Unmatched Sterilization Flexibility
Anprolene’s 100% EtO System sterilizes at room temperature without a vacuum or water injection. Protects your most delicate instruments, electronics, drills, fiber optics, cameras, and plastic or rubber items. Literally anything but food, drugs or liquids can be sterilized with Anprolene.

Sterilization and Aeration in the Same Cabinet
The Anprolene System utilizes an advanced purge system that aerates products for two hours at the end of the cycle. Active aeration continues indefinitely until products are removed, and the cycle is ended.

Proven Reliability
Anprolene has been the choice of healthcare professionals for over 40 years. Anprolene is used in over 5,000 facilities worldwide.

Unique Load Size Flexibility
The Anprolene System uses unique plastic sterilization liner bags and individual gas ampoules. We offer two different sizes of bag/ampoule combinations to match the size of your sterilization load. You never use more gas than you have to!

Each Refill Kit includes:
• Anprolene Sterilizing Gas Ampoules - 5cc or 20cc
• Liner Bags - 7 liter or 35 liter capacity

Anprolene uses Less Gas
The Anprolene system uses less than 1fl. oz. of EtO per cycle, which is less than 1/5 the gas usage of our closest competitor. The small quantity of gas used means that the Anprolene system meets all State and Federal EPA requirements without the need for expensive abatement equipment.

Sterilize with Confidence
The sterility of each Anprolene sterilization cycle can be proven with biological or Steritest indicators. You can also run chemical indicators such as the anprolene dosimeter. Operator exposure may be monitored with AirScan® or Area EtO Monitors.


Click the above image to view a larger version.

Average Cost Per Cycle: $10.50